Summary0000261: Diagrams do not import
DescriptionWhile the IG is imported into the manager database, the underlying diagrams are not.
TagsNo tags attached.

Relationships

Activities

BCP Software

BCP Software

2013-05-06 22:34

administrator   ~0000161

If your project files have moved without being saved in the new folder, the Manager attempted to find them in the original (non existing) location.
BCP Software

BCP Software

2013-05-06 22:34

administrator   ~0000162

As a workaround the project files (moved into a new folder) should be opened once more and saved before transferring them to the manager.

Issue History

Date Modified Username Field Change
2013-05-06 21:55 BCP Software New Issue
2013-05-06 21:55 BCP Software Status new => assigned
2013-05-06 21:55 BCP Software Assigned To => BCP Software
2013-05-06 22:34 BCP Software Note Added: 0000161
2013-05-06 22:34 BCP Software Status assigned => resolved
2013-05-06 22:34 BCP Software Fixed in Version => 2.1
2013-05-06 22:34 BCP Software Resolution open => fixed
2013-05-06 22:34 BCP Software Note Added: 0000162